Laser Gauge Display
Single Axis Laser outer diameter measuring instrument Display
(0 Review)
Laser diameter Measuring Instruments works with display devices which measures and display the value depending on your application. You can choose from models equipped with calculation functions for determining averages and deviations. Furthermore, they can connect with peripheral devices via interfaces such as RS232C (standard) and BCD (optional).
MKS : J-8521
Category : Laser Gauge Display
Tags : laser display
Features of the laser outer diameter measuring instrument display
- The measurement values are displayed using a 7-segment LED for easy viewing, and various error indicators make troubleshooting easier.
- With its user-friendly, simple switch and panel layout, and compact DIN-size compliant design, it's easy to mount on a panel.
- With a free power supply that accepts continuous AC 90-240V input, it can be used anywhere in the world.
Standard type
Model
LDM-130
LDM-130EX
Number of samples
400 times/sec 2000 times/sec [*1]
Average number of times
1 to 2048 times (12 steps)
Measurement mode
Measurement between arbitrary edges
display
Number of display digits
Maximum 5 digits
Calculation content
―
①Average ②Difference
③Ratio ④Large diameter measurement
Work Position Monitor
8 LEDs
8 LEDs (X, Y axis each)
recorder
Output performance
Maximum: ±10V DC; Resolution: 12 bits (approx. 10mV resolution);
Gain: 1μV to 1000mV; Impedance: approx. 100Ω; Deviation/Absolute value switchable.
External control connection
Digital deviation (analog also possible) *Connection to DAC+88 is via RS232C
Center value setting
5 digits
Upper and lower tolerance setting
Each 4 digits
Contact output
Upper and lower limit contact output
1 normally open contact × 2
Error Contact Dimension
1b contact (closed when power is OFF)
Contact Price
AC250V 2A (resistive load)
Laser remote terminal
○
○(Common for each X and Y axis)
Hold the staff
○
○(Common for each X and Y axis)
Self-diagnosis function
○
Trigger Mode
×
Offset function
×
Zero-cm function
×
○ (Only permissible when measuring the difference)
Unit switching function
×
Programming Function
×
Graph function
×
RS232C NIC
○
RS485 communication
○
BCD output
Optional (RS485 will be removed when installed)
Other reports
Options (CC-Link, Ethernet/IP)
Code length for detection unit
Standard 5m / Maximum 120m. For lengths over 30m, LDM-201/202 is required.
power supply
AC 90-240V, Flexible Power Supply, 50/60Hz
Power consumption
Approximately 20VA
[*1] Fixed by the detector (2000 times/second) is only available in the HS series.