Eccentricity Monitor (EM)

Eccentricity Monitor (EM)

(0 Review)

The Takikawa Engineering Eccentricity Monitor (EM Series) continuously measures the centering and outer diameter of coated electric wires during manufacturing. It detects deviations and triggers alarms if the insulation thickness or wire shape drifts off target

MKS : J-8521

Category : Eccentricity Monitor (EM)

Tags : eccentricity

Measurement target An electric wire coated with an insulator on a circular conductor Operating environment Temperature 5 to 40 ° C, humidity 35% to 85% RH (without condensation) Analog output Eccentricity (X, Y, R, θ axis), OD deviation (X, Y, average), Outer diameter absolute value (X, Y, average) Alarm output (relay) Outer diameter upper limit, outer diameter lower limit, excess eccentricity amount, error (incorrect position) File output Measurement data can be stored in CF, USB memory, etc. RS-232C interface Data bit 8 bits, Stop bit 1bit, Non-parity, Communication speed 19200 bps recommended. RS-485 interface Optional Display unit EM-PC 2 Panel computer (316 x 256 x 49.2 [mm] 3.5 kg) Installation resistance value Third type installed resistance value (less than 100 Ω) AC power supply AC90 to 240V 50/60Hz less than 50VA

etection unit Model EM-302B EM-303B EM-304A EM-304B Wire conditions to be measured Finished outer diameter 0.3–5 mm [*1] 0.3–15mm 0.8–30mm 0.8–45mm Corewire Parallel Scope 0.1–3 mm [*2] 0.1–10 mm 0.5–20mm 0.5–35mm Outer diameter accuracy [*3] ±0.002mm ±0.002mm ±0.005mm ±0.005mm Eccentricity accuracy ±0.01mm [*4] ±0.015mm [*4] ±0.02mm [*5] ±0.03mm [*5]