Capacitance Monitor

Capacitance Monitor detection system

(0 Review)

This system contains detector, repeater , display , capacitance monitor calibrator. This device continuously measures the capacitance of coated wires produced on a continuous extrusion line online. It allows you to set preset values ​​and digitally display the deviation from the measured value. Analog output of the measured value or deviation is provided as standard.

MKS : J-8521

Category : Capacitance Monitor

Tags : takikawa, capacitance, detector

Detector

Capacitance Monitor/Detector - Takikawa Vision Co., Ltd.

The capacitance of coated wires produced on a continuous extrusion line is measured online and continuously.

It employs a forced water supply and drainage mechanism, enabling high line speeds. The use of guard electrodes makes it highly resistant to line wobble, allowing for stable measurements regardless of water temperature or quality.

We offer a lineup of detectors to suit the outer diameter of the object being measured, from thin wires to thick wires.

Display

Capacitance Monitor/Display - Takikawa Vision Co., Ltd.

The measured value and the deviation value from the set preset value are displayed digitally simultaneously.

The tolerance range for deviation (alarm level) can be set arbitrarily, and it is possible to output a relay setting signal to an external source.

In addition to analog output of measured values ​​​​or deviation values, it is equipped with a control voltage output (DC ±10V) as standard, and it is also possible to control the capacitance of the insulated wire according to the deviation value.

detector Model Name CP-05B CP-09B CP-15B CADF
DXF

PDF

DXF

PDF

DXF

PDF
Recommended cable outer diameter Φ5mm Φ9mm Φ15mm Through the diameter Φ8mm Φ15mm Φ30mm Standard water resistance Less than 1 mS/cm (depending on water temperature, dissolved substances, etc.) Recommended: Less than 0.5 mS/cm repeater Model Name CPM-101B CADF
DXF

PDF
structure Made of die-cast aluminum / Dustproof and waterproof structure Display Model Name CPM-401B Measurement range 0–400 pF/m (measurement range can be expanded upon request) Measurement accuracy The larger of ±0.2% of the reading or ±0.2 pF/m. So 0.1pF/m Number of samples 500 times/second display Capacitance 4-digit green 7-segment LED Capacity 4-digit red 7-segment LED/LED bar graph (FS can be selected from ±10pF/m or ±100pF/m) Setting target balance 4-digit digital switch Upper and lower limit setting 3-digit digital switch Averaging process Moving average (1 to 5000 times, 1/2/5 steps) 0 yen Press the ZERO switch on the front for automatic adjustment. output Analog output Capacitance or deviation output within DC ±10V; gain selectable; isolated output. Upper and lower limit contact output Red LED indicators for both upper and lower limits, and a 1a contact output (AC250V 2A resistive load). BCD output option DL communication RS232C (standard equipment) or RS485 (optional) control method Simplified proportional control output DC ±10V voltage output, isolated type. Line News   power supply AC 90-240V, Flexible Power Supply, 50/60Hz, 10VA

 

Equipment configuration diagram

To ensure accurate measurements, please connect each device as shown in the diagram below. Failure to connect any components will result in significant errors in the measurement.

Capacitance Monitor / Equipment Configuration Diagram - Takikawa Vision Co., Ltd.

 

Calibration capacitor

This is a device used to calibrate capacitance monitors.

An electrode is mounted in the center of the glass, and a capacitor is formed between the detection electrode and the electrode in the center of the calibration capacitor, with the glass acting as the dielectric, via water.

After purchase, we can provide traceability of the calibration capacitor upon request (additional charges apply).

Capacitance Monitor / Calibration Capacitor - Takikawa Vision Co., Ltd.

Specification

Calibration capacitor Model Name CPR-05 CPR-09 CPR-15 Target detection CP-05B CP-09B CP-15B Material Dielectric material: Pyrex® glass; Electrode material: SUS304 Standard Indicated on each calibration capacitor Uncertainty Within ±0.2% of the stated standard volume Temperature Reference temperature: 23±5℃ Guaranteed temperature: 15~35℃ Measurement accuracy 0.05% instrument frequency 1MHz